Sephadex LH-20
Cat.No:S8111 Solarbio
Storage:RT,1 year
Qty:
Size:
{{cart_num}}
My Cart>
Chromatography Media >
Chromatographic Fillers >
Partition Fillers >
Sephadex LH-20Storage:RT,1 year
Qty:
Size:
Name | Sephadex LH-20 |
Storage | RT,1 year |
Instruction | Apperearance:White Powder |
Unit | Bottle |
Specification | 25g 100g 500g |
Sephadex G-type glucan gel is only suitable for use in the aqueous phase, and the hydroxylated Sephadex LH-20 is suitable for separation of lipophilic molecules in organic solvents and purification of natural products in organic solvents.
The separation of LH-20 from glucan gel is mainly by gel filtration and has the function of reverse phase distribution.
Under the action of gel filtration, the retention of macromolecular compounds is weak, and they are eluted first, and the smallest molecules exit the column last. In the reverse-phase eluting solvent, the reverse-phase distribution effect is played. The more polar substances are eluted first, and the less polar compounds are eluted later.
Application:
The use of molecular sieve is suitable for the separation of lipophilic molecules with organic solvents, and various natural products can be prepared economically on a large scale. Such as: steroids, terpenes, lipids and small molecule polypeptides
Product parameters
Properties: porous, white microspheres
Matrix: crosslinked dextran
Size: 100-200 mesh
Working Ph:2-11
Operating temperature :4-40 degrees
Globulin separation range: 100-4000
Exclusion limit: 4-5kd(depending on the solvent used)
Storage condition: 4-25 degrees
Instructions for Use
1. Preparation of gel suspension
Soak the dry powder in 60-70% ethanol, stir well overnight, wash away any residue that may be present, and balance at least two column volumes according to your own eluent until the baseline is stable.
2. Eluting solvent
If the polarity of the sample is large, use reverse-phase solvent elution (methanol-water), dissolve the sample with the least volume of methanol-water, and filter the upper column; If the sample polarity is low, use chloroform-methanol positive phase elution.
3. Sample handling
Dissolve the sample with as little eluting reagent as possible and filter under atmospheric pressure.
4. Wet loading
Step 5 Elution
Control the flow rate, generally less than 1drop/s.
6. Next use after regeneration
Note:Product information may be optimized and upgraded. Please refer to the actual label information for accuracy.
Remark:These protocols are for reference only. Solarbio does not independently validate these methods.
Note:
1. The products are all for scientific research use only. Do not use it for medical, clinical diagnosis or treatment, food and cosmetics, etc. Do not store them in ordinary residential areas.
2. For your safety and health, please wear laboratory clothes, disposable gloves and masks.
3. The experimental results may be affected by many factors, after-sale service is limited to the product itself and does not involve other compensation.