Angiotensin Converting Enzyme Inhibitor Activity Aassay Kit
Cat.No:BC5570 Solarbio
Detection Method:Spectrophotometer
Storage:Store at -20℃,6 months
Qty:
Size:
{{cart_num}}
My Cart>
Biochemical Assay Kits >
Other Biochemical Series >
Other Series >
Angiotensin Converting Enzyme Inhibitor Activity Aassay KitDetection Method:Spectrophotometer
Storage:Store at -20℃,6 months
Qty:
Size:
Name | Angiotensin Converting Enzyme Inhibitor Activity Aassay Kit |
Detection Method | Spectrophotometer |
Storage | Store at -20℃,6 months |
Unit | Kit |
Specification | 50T/48S |
Determination of Significance:
Angiotensin Converting Enzyme (ACE, EC 3.4.15.1, also called ACE1) is a zinc-containing peptidyl dipeptide hydrolase with a calculated molecular mass of 120-150 kDa. ACE is widely detected in the endothelial cell of organ tissues included lung, brain, kidney. ACE catalyzes the formation of angiotensin I to angiotensin II, which could cause vasoconstriction, promote synthesis and release of adrenocortical hormone aldosterone. ACE inhibitors could reduce the production of angiotensin II and increase bradykinin activity, which is helpful for the treatment of hypertension, cardiac hypertrophy, heart failure and other diseases.
Measurement Principle:
ACE could catalyze FAPGG to form FAP and glycylglycine. ACE inhibitors could reduce the hydrolysis of FAPGG by inhibiting ACE activity. FAPGG has a characteristic absorption peak at 340 nm, and ACE inhibitor activity is calculated by measuring the rate of decrease in absorbance at 340nm.
Self Provided:
Spectrophotometer, desk centrifuge, balance, transferpettor, 1mL quartz cuvette, constant temperature foster box/water-bath, mortar/homogenizer/cell ultrasonic crusher, ice and distilled water.
Note:Product information may be optimized and upgraded. Please refer to the actual label information for accuracy.
Remark:These protocols are for reference only. Solarbio does not independently validate these methods.
Note:
1. The products are all for scientific research use only. Do not use it for medical, clinical diagnosis or treatment, food and cosmetics, etc. Do not store them in ordinary residential areas.
2. For your safety and health, please wear laboratory clothes, disposable gloves and masks.
3. The experimental results may be affected by many factors, after-sale service is limited to the product itself and does not involve other compensation.
Sorry, there is no experimental images.
Sorry, there is no more information.
Sorry, there is no more information.