Products
Ferulic acid

CAS:1135-24-6

Purity:HPLC≥98%

Appearance:Off-white to yellow Powder

Storage:Store at 2-8℃,2 years.

Ferulic acid
Cat.No:
SF8030
Brand:
Solarbio
Examples of using this product(for reference only)

HPLC–MS

We used an HPLC system, which consisted of a binary solvent delivery system, an on-line degasser, an auto-sampler, a column temperature controller, and a diode array detector. Separation was conducted using a C18 column (5 μm, 150 mm × 4.6 mm), and the temperature was set to 40℃. The injection volume was 0.01 mL, and the flow rate was 1 mL/min. Gradient elution was conducted using a binary system consisting of 10 % formic acid in DW (A) and 10 % formic acid in acetonitrile (B). The utilized gradient was as follows: isocratic 1 % B for 6 min, 1% – 3% B for 4 min, 3 % – 15 % B for 20 min, 15 % – 40 % B for 20 min, 40 % – 90 % B for 5 min, 90 % B isocratic for 10 min, 90 % – 1 % B for 5 min, and 1 % B isocratic for 10 min. A re-equilibration operation followed. The UV detection wavelength was set to 280 nm.

The voltages of the sample cone and the capillary were set to 17 and 3000 V for the positive ion mode and 22 and 2000 V for the negative ion mode.

来源文献:[1]Zhang,Junhong,Tian,et al.Isolation and identification of phenolic compounds in Chinese purple yam and evaluation of antioxidant activity[J].LWT-Food Science & Technology, 2018, 96:161-165.

HPLC

HPLC was performed using an equipped with a DAD detector and a C18 (250 mm × 4.6 mm; 5 μm). The mobile phase included 0.2% phosphoric acid plus 0.4% sodium 1-heptanesulfonate (A) and methanol (B) at a flow speed of 1.0 ml/min in the condition of a column temperature of 30℃. The detection wavelength was set at 214 nm. The reference standard sample injection volume was 10 μl. The gradient elution was as follows: 0–5 min (100–100% A, 0%–0% B), 5–60 min (100–60% A, 0%–40% B), 60–120 min (60–30% A, 40–70% B), 120–125 min (30–30% A, 70–70% B), 125–125.1 min (30–100% A, 70–0% B), 125.1–132 min (100–100% A, 0–0% B). The chromatographic data and peak area scores were collected and analyzed using ChemStation software.

来源文献:Duan Q, Liu T, Huang C, Shao Q, Ma Y, Wang W, Liu T, Sun J, Fang J, Huang G, Chen Z. The Chinese Herbal Prescription JieZe-1 Inhibits Membrane Fusion and the Toll-like Receptor Signaling Pathway in a Genital Herpes Mouse Model. Front Pharmacol. 2021 Sep 24;12:707695. doi: 10.3389/fphar.2021.707695. PMID: 34630083; PMCID: PMC8497740.

HPLC

HPLC conditions: chromatographic column was SB-C18 column (4.6 × 250 mm, 5 μm) and the column temperature was maintained at 30℃. The wavelength of ultraviolet detector were 280 nm and 320 nm, and the gradient elution with a flow rate at 0.8 mL/min was performed by mobile phase A (2% acetic acid in deionized water) and solvent B (methanol; 0–10 min, 5–30%; 10–35 min, 30–50%; 35–40 min, 50–60%; 40–45 min, 60–70%; 45–50 min, 70–5%; 50–55 min, 5%).

来源文献:Xu J, Qi Y, Zhang J, Liu M, Wei X, Fan M. Effect of reduced glutathione on the quality characteristics of apple wine during alcoholic fermentation. Food Chem. 2019 Dec 1;300:125130. doi: 10.1016/j.foodchem.2019.125130. Epub 2019 Jul 4. PMID: 31325746.

HPLC

HPLC analysis employed an Agilent 1260 HPLC instrument and a diode array detector (Agilent, Santa Clara, CA, USA). The chromatographic separation was achieved by a Zobax Stablebond Analytical SB-C18 column (250 × 4.6 mm, 5 μm). The mobile phases, containing a gradient of solvent A (acetic/water, 2:98, v/v) and solvent B (acetic acid/acetonitrile/water, 5:50:45, v/v) were used to elute the column. The solvent gradient was programmed from 90% to 55%A and 10% to 45%B for 50 min, 55% to 0%A and 45% to 100%B for 10 min, and 0% to 90%A and 100% to 10%B for 5 min. The flow velocity was 1.0 mL·min-1 , the column temperature was 30℃, and the injection volume was 20 μL

来源文献:Liang D, Deng H, Deng Q, Lin L, Lv X, Wang J, Wang Z, Xiong B, Zhao X, Xia H. Dynamic Changes of Phenolic Compounds and Their Associated Gene Expression Profiles Occurring during Fruit Development and Ripening of the Donghong Kiwifruit. J Agric Food Chem. 2020 Oct 14;68(41):11421-11433. doi: 10.1021/acs.jafc.0c04438. Epub 2020 Sep 30. PMID: 32936614.

Remark:
These protocols are for reference only. Solarbio does not independently validate these methods.

Note:
1. The products are all for scientific research use only. Do not use it for medical, clinical diagnosis or treatment, food and cosmetics, etc. Do not store them in ordinary residential areas.
2. For your safety and health, please wear laboratory clothes, disposable gloves and masks.
3. The experimental results may be affected by many factors, after-sale service is limited to the product itself and does not involve other compensation.
Experimental Images
Sorry, there is no more information.
Service  for  Scientific  Research,  Responsible  for  the  Life  Science
Contact Us
Address: No 85, Liandong U Valley, Middle Zone, 101102, Tongzhou Dist, Beijing, China
Tel: +86 010 50973105
Technical Support Email: service@solarbio.com
Purchaser Email: purchase@solarbio.com
Sales Email: sales@solarbio.com
Copyright © 2005-2021 Solarbio all rights reserved.
 ICP Filing Certificate京ICP备12051307号-7